Ion Pro™ Steady-State 2-Fan Overhead Ionizing Blower, 120V
SCS Ion Pro™ Overhead Ionizers are steady-state DC ionizers designed for use in ESD protected areas. The SCS 770112 two-fan ionizer has a 2' x 4' coverage area. The Ion Pro™ Overhead Ionizers' discharge times (< 3 seconds at 18") and low offset voltage (±10 volts) meet the required limits of ANSI/ ESD S20.20 < ±35 volts tested per ANSI/ESD STM3.1 and ESD TR53. Its emitters are made of pure tungsten and spaced further apart to minimize ion recombination, increase discharge efficiency and provide a broader coverage area. The fans have 3 speeds (high, medium, low) which produce consistent performance at all 3 settings. The Ion Pro™ Overhead Ionizers utilize an auto-feedback system that continuously optimizes its performance and automatically alarms and shuts down should its supply voltage drop.
The SCS Ion Pro™ Overhead Ionizers include 700 lumen light panels (cool white) that provide additional illumination to the work area and improve visibility and productivity. The 770112 features one light panel.
Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS [ESD sensitive] items.
In order to mitigate field-induced CDM [Charged Device Model] damage, the ESD program shall include a plan for the handling of process-required insulators. If the field exceeds 2,000 volts/inch, steps shall be taken to either: A) Separate the insulator from the ESD-sensitive device by a distance of 30cm (12 inches); or B) Use ionization or other charge mitigating techniques to neutralize the charge.
The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods. In clean rooms, air ionization may be one of the few methods of static control available.
Includes
- 1 Ion Pro™ Overhead Ionizer
- 1 Hanging Kit
- 1 Power Cord, North American Plug
- 2 Emitter Point Cleaners
- 1 Certificate of Calibration
- Two fan steady-state DC ionization for 2' x 4' coverage area and neutralizes electrostatic charges on insulators and ungrounded conductors within the coverage area.
- 3 seconds or less discharge time with ±10 volts offset voltage (balance) and meets the required limits for ionization use in electronics manufacturing areas per ANSI/ESD S20.20 and ESD TR53.
- One 700 Lumen LED Panel Light (cool white). Adds additional light to operator work area for improved visibility.
- 3 position fan speed: Low, Medium, High
- Ionization performance is consistent at all speeds and allows for use with sensitive applications, such as calibration, test, or repair procedures.
- Sealed plenum air flow prevents contamination from being introduced to workstation.
- Auto-feedback system (audible and visual alarm through single Tri-Color LED).
- Unit will automatically shut down and alarm if/when supply voltage drops
- 120/220V input voltage selectable so unit can be used with 110V or 220V power sources.
- Replaceable emitter pins allow for minimal downtime
- NIST calibrated with certificate included.
- Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology.
- Made in the United States of America Chino, CA
Specifications
- Typical positive and negative discharge times (1000V to 100V) measured using ANSI/ESD STM 3.1 are shown in the "Neutralization (Discharge) Times" section. The performance of the ionizer was measured with the unit positioned as shown, with the fan speed on high and without a filter.
- Air Flow: Three speed fan (100 cfm - 200 cfm)
- Balance (offset voltage): ±10 Volts Typical ±20 Volts Maximum (Temperature Range: 65°F - 80°F, RH: 15% - 65%)
- Chassis: Powder coated steel
- Dimensions: 770112 - 3.9"H x 6.6"W x 22.3"L (9.9 x 16.8 x 56.6cm)
- Emitter Points 0.050"Diameter Made of pure tungsten for improved mechanical strength and ionization stability.
- Fuse: 400mA slow blow
- High Voltage Power Supply: 5.5kV DC nominal
- Input Power: AC line power
- Internally selectable for 100/120V - 50/60Hz or 220/230V - 50/60Hz
- Ion Emission: Steady-state DC with sense feedback
- Lights: 700 lumen each Cool white color 12 year estimated life expectancy (based on an average use of 10 hours per day)
- Mounting: May be rigid-mounted or suspended from ceiling
- Ozone: < 0.05 ppm
- Weight 770112 - 7lbs (3.2kg)
SKU | I386151 |
---|---|
Mfg. Part Number | 770112 |
Brand | SCS |
Input | 120V |