Transforming Technologies IN4200

Ptec™ AirFLEX Ionizing Nozzle with Flexible Neck, 100/240V

Ionizing nozzle provides pinpoint ionization with hands-free foot peddle operation.

The IN4200 flexible nozzle neck frees the operator's hands during assembly and manufacturing processes. A foot pedal controls both ionization and airflow, which reduces compressed air costs and extends the life of the ionizer. The model IN4000 ionizing air nozzle produces a 68KHz AC output of approximately 2200V and a continuous stream of balanced air ions. The AirFLEX ionizers are valuable because they can be mounted in hard to reach areas that larger ionizers just can not handle.

  • Flexible neck allows you to optimally position airflow.
  • Multiple nozzle options to customize airflow for your specific application.
  • Hands-Free operation with foot pedal operation
  • Optional 0.01 micron filter for clean air
  • Ionization (green) and HV alarm (red) lights.
  • No periodic adjustments.
$1,172.00

Maintenance Savings

Ptec™ ionizers save time and money because they require no calibration. Emitter life is increased and maintenance frequency is reduced, due to 68KHz AC ion emission.

Features

The IN4200 features the inherently stable output of all Ptec™ Ionizers and high-frequency AC (68KHz) ion emission. The flexible metal neck, with multiple nozzle options allows for easy operation and service of emitters. A foot switch and 0.01 micron filter combine to deliver clean air at the correct pressure when needed.

Applications

The IN4200 is designed to neutralize electrostatic charges in bench top environments, sensitive materials assembly, Medical Device, SMT, Electronics Assembly, Automotive packaging, cleanroom and laboratory environments.

Verification and Calibration

The IN4200 ionizer comes factory calibrated and with a calibration certificate. Ionizer performance can be tested and verified with a charge plate monitor. Important tests to perform are positive and negative decay times and ion balance. It is recommended to test ionizer performance at least 1 per year.

Power Requirements

The IN4200 can work on all power circuits, from 100-240 volts, without any adjustments. This means the standard ionizer can be used in many different countries and power circuits and performance will not be affected.

Specifications

  • Power Input: AC 100 to 240V, 50/60Hz
  • Power Outlet: un-fused, 0.5A or 1.0A max.
  • Ion Emission: AC, 68KHz
  • Balance: +30 volts
  • Decay Time: 1000V-100V, < 2.0 seconds at 12"
  • Temperature: 66-78°F (19-25°C)
  • Humidity: 20-60% RH (non-condensing
  • Air Pressure: 10-100 PSI, CDA or N2
  • Indicators Power: Green LED, Alarm: Red
  • Controls: Footswitch
  • Mounting: Table Mount
  • Emitter Points: Tungsten Alloy
  • Dimensions: 12"H x 5.75"W x 7.25"D,
  • Filter Option: 0.01 micron filter (replaceable)* *Note: Unit also may be operated without filter.
  • Gas Input & Connection: 20-75 psi, CDA or N2, 1/4" male industrial interchange quick disconnect or 1/4" quick release tube fitting
  • Warranty: 1-year limited warranty
More Information
SKU I378479
Mfg. Part Number IN4200
Brand Transforming Technologies
Input 100 to 240V
©Production Automation Corporation. All Rights Reserved.